{"_buckets": {"deposit": "f79406ef-2478-43e2-b3b9-04de7ba8e1f7"}, "_deposit": {"created_by": 4, "id": "120", "owners": [4], "pid": {"revision_id": 0, "type": "depid", "value": "120"}, "status": "published"}, "_oai": {"id": "oai:morinomiya.repo.nii.ac.jp:00000120", "sets": ["18"]}, "author_link": ["326", "327", "328", "325"], "item_10002_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2019-03-20", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "22", "bibliographicPageStart": "15", "bibliographicVolumeNumber": "13", "bibliographic_titles": [{"bibliographic_title": "森ノ宮医療大学紀要"}, {"bibliographic_title": "Bulletin of Morinomiya University of Medical Sciences", "bibliographic_titleLang": "en"}]}]}, "item_10002_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "背景と目的:\nこれまで徒手筋力計を用いた幾つかの足関節背屈筋力測定については信頼性が検証されているが、座位での検証は不十分であり、足趾肢位が異なる場合の検証も行われていない。一方で、その検証されていない方法で測定した値が慢性スポーツ障害と関連することが示唆されている。本研究の目的は、足関節背屈の徒手筋力測定法について長座位及び端座位で信頼性を検討すること、並びに、その筋力値から算出される屈曲伸展比の信頼性を検討することである。 \n方法:\n若年健常成人10名を対象とし、徒手筋力計の引張力センサ及び牽引ベルトを用いて利き足の筋力を測定した。測定体位は長座位か端座位のいずれかとし、足趾肢位は伸展位か屈曲位のいずれかとして、それらの組み合わせによる4つの測定姿勢で筋力測定を行った。筋力測定では、どの測定条件においても足関節中間位で3秒間の最大等尺性足関節背屈運動を行わせた。各条件での測定は2日間以上の間隔を空けて2回ずつ実施した。得られた測定値の検者内信頼性を検討するために級内相関係数ICC(1,1)を算出した。 \n結果:\n体位と足趾肢位ごとにICC(1,1)を計算した結果、長座位-足趾伸展位では0.74(95%信頼区間:0.28 〜0.93)、長座位- 屈曲位では0.56(-0.02 〜0.87)、端座位- 足趾伸展位では0.75(0.29 〜0.93)、端座位- 屈曲位では0.77(0.34 〜0.94)であった。また、F/E比のICC(1,1)を計算した結果、長座位では-0.23(-0.71 〜0.43)、端座位では0.36(-0.28 〜0.79)となった。 \n結論:\n長座位・端座位での徒手筋力計を用いた足関節背屈筋力測定では十分な信頼性が得られず、これらの測定値から算出される屈曲伸展比についても信頼性が低かった。臨床の現場で活用するためには改良が必要である。", "subitem_description_type": "Abstract"}, {"subitem_description": "Purpose:\nAlthough the reliability of a hand-held dynamometer(HHD)for measuring muscle strength of ankle dorsiflexion has been verified, the reliability is unknown in some settings. In contrast, the variables from those measurements are suggested to be associated with a chronic athletic injury. We aimed to examine the reliability of using a HHD for measuring the muscle strength of ankle dorsiflexor in different sitting postures and the reliability of the resultant strength ratio.\nMethods:\nTen young healthy individuals were enrolled, and their ankle dorsiflexor strength was measured using a HHD in either the sitting or the long-sitting position, with their toe extended or flexed, resulting in four different measurement conditions. Each measurement was performed at an interval of at least two days. The selected device could measure the tractive force, and for every measurement, the participants were asked to perform maximal isometric dorsiflexion to pull the belt linked to the HHD. The intrarater reliability of the measurements was measured by calculating the intraclass correlation coefficient(ICC).\nResults:\nThe ICC(1,1)of strength measurement using a HHD was 0.74(95% confidence interval;0.28–0.93)for the long-sitting plus toe extension condition, 0.56(-0.02–0.87)for the long-sitting plus toe flexion condition, 0.75(0.29–0.93)for the sitting plus toe extension condition, and 0.77(0.34–0.94)for the sitting plus toe flexion condition. For the ratio of the strength in the toe flexion condition to that in the toe extension condition, the ICCs(1,1)were -0.23(-0.71–0.43)for long-sitting and 0.36(-0.28–0.79)for sitting.\nConclusion:\nThe measurement of the ankle dorsiflexor strength using a HHD in the long-sitting and sitting positions indicated insufficient reliability, and the resultant ratio indicated low reliability. Methodologicalimprovement is necessary for their use in clinical settings.", "subitem_description_type": "Abstract"}]}, "item_10002_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "森ノ宮医療大学 紀要編集部会"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "稲垣, 優"}, {"creatorName": "イナガキ, ユウ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "325", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "木内, 隆裕"}, {"creatorName": "キナイ, タカヒロ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "326", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Inagaki, Yu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "327", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kinai, Takahiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "328", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-03-20"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "bmumss_13_15-22.pdf", "filesize": [{"value": "1.3 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1300000.0, "url": {"label": "bmumss_13_15-22.pdf", "url": "https://morinomiya.repo.nii.ac.jp/record/120/files/bmumss_13_15-22.pdf"}, "version_id": "95f6357f-f768-4b5a-81f1-8e79145096ef"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "筋力", "subitem_subject_scheme": "Other"}, {"subitem_subject": "徒手筋力計", "subitem_subject_scheme": "Other"}, {"subitem_subject": "信頼性", "subitem_subject_scheme": "Other"}, {"subitem_subject": "足関節", "subitem_subject_scheme": "Other"}, {"subitem_subject": "座位", "subitem_subject_scheme": "Other"}, {"subitem_subject": "muscle strength", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "hand-held dynamometry", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "reliability", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ankle", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "sitting", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "徒手筋力計を用いた座位足関節背屈筋力測定の検者内信頼性", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "徒手筋力計を用いた座位足関節背屈筋力測定の検者内信頼性"}, {"subitem_title": "Intrarater reliability of hand-held dynamometry for measuring ankle dorsiflexion strength in sitting posture", "subitem_title_language": "en"}]}, "item_type_id": "10002", "owner": "4", "path": ["18"], "permalink_uri": "https://morinomiya.repo.nii.ac.jp/records/120", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-03-20"}, "publish_date": "2019-03-20", "publish_status": "0", "recid": "120", "relation": {}, "relation_version_is_last": true, "title": ["徒手筋力計を用いた座位足関節背屈筋力測定の検者内信頼性"], "weko_shared_id": 4}
徒手筋力計を用いた座位足関節背屈筋力測定の検者内信頼性
https://morinomiya.repo.nii.ac.jp/records/120
https://morinomiya.repo.nii.ac.jp/records/120a5575aff-f638-48e8-82bf-9a36908a679e
名前 / ファイル | ライセンス | アクション |
---|---|---|
bmumss_13_15-22.pdf (1.3 MB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-03-20 | |||||
タイトル | ||||||
タイトル | 徒手筋力計を用いた座位足関節背屈筋力測定の検者内信頼性 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Intrarater reliability of hand-held dynamometry for measuring ankle dorsiflexion strength in sitting posture | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 筋力 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 徒手筋力計 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 信頼性 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 足関節 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 座位 | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | muscle strength | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | hand-held dynamometry | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | reliability | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | ankle | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | sitting | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
稲垣, 優
× 稲垣, 優× 木内, 隆裕× Inagaki, Yu× Kinai, Takahiro |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 背景と目的: これまで徒手筋力計を用いた幾つかの足関節背屈筋力測定については信頼性が検証されているが、座位での検証は不十分であり、足趾肢位が異なる場合の検証も行われていない。一方で、その検証されていない方法で測定した値が慢性スポーツ障害と関連することが示唆されている。本研究の目的は、足関節背屈の徒手筋力測定法について長座位及び端座位で信頼性を検討すること、並びに、その筋力値から算出される屈曲伸展比の信頼性を検討することである。 方法: 若年健常成人10名を対象とし、徒手筋力計の引張力センサ及び牽引ベルトを用いて利き足の筋力を測定した。測定体位は長座位か端座位のいずれかとし、足趾肢位は伸展位か屈曲位のいずれかとして、それらの組み合わせによる4つの測定姿勢で筋力測定を行った。筋力測定では、どの測定条件においても足関節中間位で3秒間の最大等尺性足関節背屈運動を行わせた。各条件での測定は2日間以上の間隔を空けて2回ずつ実施した。得られた測定値の検者内信頼性を検討するために級内相関係数ICC(1,1)を算出した。 結果: 体位と足趾肢位ごとにICC(1,1)を計算した結果、長座位-足趾伸展位では0.74(95%信頼区間:0.28 〜0.93)、長座位- 屈曲位では0.56(-0.02 〜0.87)、端座位- 足趾伸展位では0.75(0.29 〜0.93)、端座位- 屈曲位では0.77(0.34 〜0.94)であった。また、F/E比のICC(1,1)を計算した結果、長座位では-0.23(-0.71 〜0.43)、端座位では0.36(-0.28 〜0.79)となった。 結論: 長座位・端座位での徒手筋力計を用いた足関節背屈筋力測定では十分な信頼性が得られず、これらの測定値から算出される屈曲伸展比についても信頼性が低かった。臨床の現場で活用するためには改良が必要である。 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose: Although the reliability of a hand-held dynamometer(HHD)for measuring muscle strength of ankle dorsiflexion has been verified, the reliability is unknown in some settings. In contrast, the variables from those measurements are suggested to be associated with a chronic athletic injury. We aimed to examine the reliability of using a HHD for measuring the muscle strength of ankle dorsiflexor in different sitting postures and the reliability of the resultant strength ratio. Methods: Ten young healthy individuals were enrolled, and their ankle dorsiflexor strength was measured using a HHD in either the sitting or the long-sitting position, with their toe extended or flexed, resulting in four different measurement conditions. Each measurement was performed at an interval of at least two days. The selected device could measure the tractive force, and for every measurement, the participants were asked to perform maximal isometric dorsiflexion to pull the belt linked to the HHD. The intrarater reliability of the measurements was measured by calculating the intraclass correlation coefficient(ICC). Results: The ICC(1,1)of strength measurement using a HHD was 0.74(95% confidence interval;0.28–0.93)for the long-sitting plus toe extension condition, 0.56(-0.02–0.87)for the long-sitting plus toe flexion condition, 0.75(0.29–0.93)for the sitting plus toe extension condition, and 0.77(0.34–0.94)for the sitting plus toe flexion condition. For the ratio of the strength in the toe flexion condition to that in the toe extension condition, the ICCs(1,1)were -0.23(-0.71–0.43)for long-sitting and 0.36(-0.28–0.79)for sitting. Conclusion: The measurement of the ankle dorsiflexor strength using a HHD in the long-sitting and sitting positions indicated insufficient reliability, and the resultant ratio indicated low reliability. Methodologicalimprovement is necessary for their use in clinical settings. |
|||||
書誌情報 |
森ノ宮医療大学紀要 en : Bulletin of Morinomiya University of Medical Sciences 巻 13, p. 15-22, 発行日 2019-03-20 |
|||||
出版者 | ||||||
出版者 | 森ノ宮医療大学 紀要編集部会 |