WEKO3
アイテム
{"_buckets": {"deposit": "99e2de12-767b-4486-aa2a-1d41d5ce7d23"}, "_deposit": {"created_by": 1, "id": "1009", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "1009"}, "status": "published"}, "_oai": {"id": "oai:showa.repo.nii.ac.jp:00001009", "sets": ["125"]}, "author_link": ["5628", "5627", "5626"], "item_10002_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2013-07", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "213", "bibliographicPageStart": "209", "bibliographicVolumeNumber": "33", "bibliographic_titles": [{"bibliographic_title": "Dental medicine research"}]}]}, "item_10002_description_6": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "覚醒時の上下歯列接触癖(Tooth Contacting Habit;TCH)は顎関節症の原因因子として注目されてきている。TCHの評価は質問票や問診に基づくため信頼性が低く、TCHを客観的に評価することができなかった。著者らはTCHを客観的に定量化するために「TCH測定システム」を開発し、臨床への導入をすすめている。このTCH測定システムはコンピューターと専用ソフトウェアからなり、Eメール機能を有する市販の携帯電話さえあれば、ランダムに送信されるEメールを受信した時にTCHの有無を確認し、空メールを返信するだけで、データが蓄積され、TCHの出現頻度や出現状況を自動分析することができる。本稿ではTCH測定システムの概要と初期の運用実績および今後の発展性について紹介する。(著者抄録)", "subitem_description_type": "Abstract"}]}, "item_10002_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "昭和大学・昭和歯学会"}]}, "item_10002_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type": "isIdenticalTo", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.7881/dentalmedres.33.209", "subitem_relation_type_select": "DOI"}}]}, "item_10002_source_id_11": {"attribute_name": "NCID", "attribute_value_mlt": [{"subitem_source_identifier": "AA12322983", "subitem_source_identifier_type": "NCID"}]}, "item_10002_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1882-0719", "subitem_source_identifier_type": "ISSN"}]}, "item_10002_text_26": {"attribute_name": "アイテムタイプ", "attribute_value_mlt": [{"subitem_text_value": "学内発行雑誌 / Departmental Bulletin Paper"}]}, "item_10002_text_27": {"attribute_name": "POS_INDEX", "attribute_value_mlt": [{"subitem_text_value": "学内発行雑誌/Dental medicine research/33巻(2013)/2号"}]}, "item_10002_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "船登, 雅彦"}], "nameIdentifiers": [{"nameIdentifier": "5626", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小野, 康寛"}], "nameIdentifiers": [{"nameIdentifier": "5627", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "馬場, 一美"}], "nameIdentifiers": [{"nameIdentifier": "5628", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-07-26"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "D33_209.pdf", "filesize": [{"value": "2.9 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 2900000.0, "url": {"label": "D33_209.pdf", "url": "https://showa.repo.nii.ac.jp/record/1009/files/D33_209.pdf"}, "version_id": "613bb6e2-14dc-45e6-95eb-454609393cd2"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "TCH測定システム", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "TCH測定システム"}]}, "item_type_id": "10002", "owner": "1", "path": ["125"], "permalink_uri": "https://showa.repo.nii.ac.jp/records/1009", "pubdate": {"attribute_name": "公開日", "attribute_value": "2016-08-17"}, "publish_date": "2016-08-17", "publish_status": "0", "recid": "1009", "relation": {}, "relation_version_is_last": true, "title": ["TCH測定システム"], "weko_shared_id": -1}
TCH測定システム
https://showa.repo.nii.ac.jp/records/1009
https://showa.repo.nii.ac.jp/records/100963da4bb7-baa3-41e2-8dba-ea75e906a2ff
名前 / ファイル | ライセンス | アクション |
---|---|---|
D33_209.pdf (2.9 MB)
|
|
Item type | 学内発行雑誌 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-08-17 | |||||
タイトル | ||||||
タイトル | TCH測定システム | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ | departmental bulletin paper | |||||
著者 |
船登, 雅彦
× 船登, 雅彦× 小野, 康寛× 馬場, 一美 |
|||||
書誌情報 |
Dental medicine research 巻 33, 号 2, p. 209-213, 発行日 2013-07 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 覚醒時の上下歯列接触癖(Tooth Contacting Habit;TCH)は顎関節症の原因因子として注目されてきている。TCHの評価は質問票や問診に基づくため信頼性が低く、TCHを客観的に評価することができなかった。著者らはTCHを客観的に定量化するために「TCH測定システム」を開発し、臨床への導入をすすめている。このTCH測定システムはコンピューターと専用ソフトウェアからなり、Eメール機能を有する市販の携帯電話さえあれば、ランダムに送信されるEメールを受信した時にTCHの有無を確認し、空メールを返信するだけで、データが蓄積され、TCHの出現頻度や出現状況を自動分析することができる。本稿ではTCH測定システムの概要と初期の運用実績および今後の発展性について紹介する。(著者抄録) | |||||
DOI | ||||||
関連識別子 | 10.7881/dentalmedres.33.209 | |||||
出版者 | ||||||
出版者 | 昭和大学・昭和歯学会 | |||||
ISSN | ||||||
収録物識別子 | 1882-0719 | |||||
著者版フラグ | ||||||
出版タイプ | VoR |